/** CCU6: Synchronisation of ADC1-EIM with CCU6 Ch0                            **/
/********************************************************************************/
/** Timer12 is running at a 50us period in center-aligned mode.                **/
/** The three compare channel have a compare match at:                         **/
/** Channel | DC  | CC6x | COUT6x                                              **/
/** -----------------------------                                              **/
/**   Ch0   |  n  | P0.4 | P0.2                                                **/
/**   Ch1   | 50% | P1.0 | P1.1                                                **/
/**   Ch2   | 75% | P1.3 | P1.4                                                **/
/**                                                                            **/
/** Timer13 (sync. to Ch0) triggers ADC1-Ch4 (Poti), which adjusts the duty    **/
/** cycle of Channel 0.                                                        **/
/********************************************************************************/